NIPRESS D–900 Inner ceramic diaphragm, max. 290 psi

(Pressure Transmitters)

D9
  • 5 years warranty
  • Explosion protection

2 / 3-wire integrated pressure transmitter for absolute and gauge pressure measurement. Output: 4…20 mA or 0…10 V, diaphragm: ceramic, measuring range: 0…290 psi

Type
D
9
Measuring method
D
9

Gauge

Absolute (p ≥ 14.5 psi)

Process connection
D
9

¼" BSP

½" BSP

½" NPT

M20x1.5

Range / Overpressure
D
9

0…0.58 psi / 29 psi

0…0.87 psi / 29 psi

0…1.45 psi / 58 psi

0…2.32 psi / 58 psi

0…3.62 psi / 87 psi

0…5.8 psi / 87 psi

0…8.7 psi / 116 psi

0…14.5 psi / 116 psi

0…23.2 psi / 217 psi

0…36.2 psi / 362 psi

0…58 psi / 362 psi

0…87 psi / 507 psi

0…145 psi / 507 psi

0…232 psi / 652 psi

0…290 psi / 652 psi

Accuracy
D
9

0.25% (p ≥ 8.7 psi)

0.5%

Output / Certificates
D
9

4…20 mA, 2-wire

0…10 V, 3-wire

4…20 mA, 2-wire / Ex ia G

Related

Available on request

PVDF process connection (only ½" BSP, p ≤ 145 psi)

EPDM seal (max. 2320 psi)

M12x1 (4-pin) IP67 electrical connection, metal

Integrated cable version (IP68), PVC cable (+23…+158 °F)

PVC cable add-on price per meter

Custom measurement range (based on prior negotiations)

Accessories

UNICONT PLK–501 Plug-in display

2-wire plug-in loop indicator can be inserted between connectors complies with DIN 43650 / ISO 4400 , input: 4…20 mA

Type
P
L
K
5
0
1
2

Plug-in display

UNICONT PLK–501 Plug-in display with PNP output

2-wire plug-in loop indicator can be inserted between connectors complies with DIN 43650 / ISO 4400 , input: 4…20 mA

Type
P
L
K
5
0
1
3

Plug-in display with PNP output